0755-2790 2267
0755-2790 2204
Self-consumption and feed-in to the grid
Programmable supply priority for PV, Battery or Grid
User-adjustable battery charging current suits different types of batteries
Programmable multiple operations modes: grid-tie, off-grid, and grid-tie with backup
Built-in time for various mode of on/off operation
Multiple communication for USB, RS-232, Modbus and SNMP
Monitoring software for real time status display and control
80A of AC & PV Charger capability
Support parallel up to 6 units
PV input power is 50% higher of inverter rating to support more power for battery charging even with full load connected.
Contact Microtek hybrid solar inverter factory for more custom solar inveters
PRODUCT NAME | 4KW single phase hybrid solar inverter with 1 MPPT trackers |
MODEL | 4KW single phase hybrid solar inverter with Energy Storage |
PHASE | 1-phase in / 1-phase out |
MAXIMUM PV INPUT POWER | 5000W |
RATED OUTPUT POWER | 4000W |
MAXIMUM CHARGING POWER | 4000W |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 580 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150VDC |
MPPT Voltage Range | 280 VDC ~ 500 VDC |
Number of MPPT Trackers / Maximum Input Current | 1 / 1× 18A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 202/208/220/230/240 VAC |
Output Voltage Range | 184 - 264.50 VAC * |
Nominal Output Current | 17.5A` |
Power Factor | >0.99 |
EFFICIENCY | |
Maximum Conversation Efficiency(DC/AC) | 96% |
European Efficiency@ Vnominal | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC |
Maximum AC Input Current | 40A |
PV INPUT (DC) | |
Maximum DC Voltage | 580 VDC |
MPP Voltage Range | 280 VDC ~ 500 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1 × 18A |
BATTERY MODE OUTPUT(AC) | |
Nominal Output Voltage | 202/208/220/230/240 VAC |
Output Waveform | Pure sine wave |
Efficiency(DC to AC) | 91% |
HYBRID OPERATION | |
PV INPUT(DC) | |
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 580VDC |
Start-up Voltage / Initial Feeding Voltage | 116VDC / 150VDC |
MPP Voltage Range | 280 VDC ~ 500 VDC |
Number of MPP Trackers / Maximum Input Current | 1 / 1×18A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 202/208/220/230/240 VAC |
Output Voltage Range | 184 - 264.5 VAC * |
Nominal Output Current | 17.5A |
AC INPUT | |
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC |
Maximum AC Input Current | 40 A |
BATTERY MODE OUTPUT(AC) | |
Nominal Output Voltage | 202/208/220/230/240 VAC |
Efficiency(DC to AC) | 91% |
BATTERY & CHARGER | |
Nominal DC Voltage | 48 VDC |
Maximum Charging Current | 80A |
GENERAL | |
PHYSICAL | |
Dimension, D×W×H(mm) | 117×438×535 |
Net Weight(kgs) | 16.2 |
INTERFACE | |
Communication Port | USB/Dry contact |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT | |
Humidity | 0 ~ 90% RH(No condensing) |
Operating Temperature | 0℃ to 40℃ |
Altitude | 0 ~ 1000 m*** |