0755-2790 2267
0755-2790 2204
IP65 waterproof and dustproof makes the inverter available for various working conditions
Built-in WiFi for mobile monitoring(App is available)
150% unbalanced load support
Maximum PV input current 18A
User-adjustable charging current
Communication port for BMS(RS485)
Parallel operation up to 6 units
Contact Microtek hybrid solar inverter factory for more custom solar inveters
PRODUCT NAME | 10KW Three phase hybrid solar inverter with 2 MPPT trackers |
MODEL | 10KW Three phase hybrid solar inverter with Energy Storage |
MAXIMUM PV INPUT POWER | 14500 |
RATED OUTPUT POWER | 10000W |
MAXIMUM CHARGING POWER | 10000W |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC |
MPPT Voltage Range | 350 VDC ~ 900 VDC |
Number of MPPT Trackers / Maximum Input Current | 2 / A:18A, B: 18A |
Number of Strings Per MPP Tracker | A:2, B:2 |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC(P-N) / 400 VAC(P-P) |
Output Voltage Range | 184 ~ 265 VAC per phase |
Nominal Output Current | 14.5A per phase` |
Power Factor | 0.9 lag ~ 0.9 lead |
EFFICIENCY | |
Maximum Conversation Efficiency(DC/AC) | >96% |
European Efficiency@Vnominal | >96% |
OFF-GRID OPERATION | |
AC INPUT | |
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC per phase |
Maximum AC Input Current | 20A |
PV INPUT (DC) | |
Maximum DC Power | 14500 W |
Maximum DC Voltage | 900 DC |
MPP Voltage Range | 350 VDC ~ 900 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / A:18A, B: 18A |
Number of Strings Per MPP Tracker | A:2, B:2 |
BATTERY MODE OUTPUT(AC) | |
Nominal Output Voltage | 230 VAC(P-N) / 400 VAC(P-P) |
Output Waveform | Pure sine wave |
Efficiency(DC to AC) | 94% |
HYBRID OPERATION | |
PV INPUT(DC) | |
Maximum DC Voltage | 720 VDC |
Start-up Voltage / Initial Feeding Voltage | 320VDC / 350VDC |
MPP Voltage Range | 350 VDC ~ 900 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / A:18A, B: 18A |
Number of Strings Per MPP Tracker | A:2, B:2 |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC(P-N) / 400 VAC(P-P) |
Output Voltage Range | 184 - 265 VAC Per phase |
Nominal Output Current | 14.5A per phase` |
AC INPUT | |
AC Start-up Voltage / Auto Restart Voltage | 120-140 VAC / 180 VAC |
Acceptable Input Voltage Range | 170 - 280 VAC per phase |
Maximum AC Input Current | 20 A |
BATTERY MODE OUTPUT(AC) | |
Nominal Output Voltage | 230 VAC(P-N) / 400 VAC(P-P) |
Efficiency(DC to AC) | 94% |
BATTERY & CHARGER | |
Battery Voltage Range | 204 ~ 408 VDC |
Maximum Charging Current | 30A |
GENERAL | |
PHYSICAL | |
Dimension, D×W×H(mm) | 255 × 660 × 600 |
Net Weight(kgs) | 45 |
IP protection | IP65 |
INTERFACE | |
Communication Port | RS-232, RS-485, USB, CAN and Wi-Fi |
Intelligent Slot | Optional for SNMP and Modbus cards |
ENVIRONMENT | |
Humidity | 0 ~ 100% RH(No condensing) |
Operating Temperature | -25℃ to 60℃, >45℃ power derating) |
Altitude | 0 ~ 1000 m** |